Magnetic Field Settings

Summary of B-fields

MOT Anti-H MOT transfer x-bias y-bias z-bias
B-field per A, at MOT 1.56 G/cm 3.03 G 1.807 G 1.141 G 1.807 G
error (1 cm off-centre) 5 % 0.2% 0.4 %
B-field per A, at chip 7 G/A 1.766 G 1.140 G 2.141 G
error (1 mm off-centre) 0.05 G/A 5 % 0.2% 0.4 %

Back to Magnetic Trapping and Transport